Other information:
Overview
The generator is driven by the FEAD belt. When the engine is
started, the generator begins to generate AC voltage which is internally
converted to DC voltage. The DC voltage is controlled by the voltage
regulator and supplied to the battery. The PCM controls the voltage
regulator set point, communicating with the generator internal voltage
regulator over a LIN communication circuit...
Special Tool(s) /
General Equipment
Resistance Spotwelding Equipment
Knife
8 mm Drill Bit
MIG/MAG Welding Equipment
Spot Weld Drill Bit
Locking Pliers
Materials
Name
Specification
Metal Bonding AdhesiveTA-1, TA-1-B, 3M™ 08115, LORD Fusor® 108B, Henkel Teroson EP 5055
-
Seam SealerTA-2-B, 3M™ 08308, LORD Fusor® 803DTM
-
R..