Other information:
Leak detection
Review next note for important refrigerant system dye information.
NOTE:
Fluorescent refrigerant system dye is added to the
refrigerant system at the factory to assist in refrigerant system leak
diagnosis using a Rotunda-approved UV
lamp. Do not add dye to the refrigerant system before diagnosing leaks
or after repairs, even if a significant amount of refriger..
Special Tool(s) /
General Equipment
Interior Trim Remover
Removal
WARNING:
Disconnect the 12 volt battery before servicing the direct
current to alternating current (DC-AC) inverter or alternating current
(AC) powerpoint to prevent the risk of high voltage shock. Failure to
follow this instruction may result in serious personal injury.
Disconnect the negative b..