Ford Escape: Body Closures / General Procedures - Power Liftgate Initialization
Programming
NOTE:
This procedure clears and then sets new open and close end points in the RGTM memory.
-
Turn the ignition ON.
-
Using a scan tool perform the RGTM self test to complete power liftgate
initialization. From the diagnostic scan tool, enter TOOLBOX > Self
Test > RGTM > Run Selected Procedure.
Special Tool(s) /
General Equipment
Interior Trim Remover
Inspection
NOTE:
Removal steps in this procedure may contain installation details...
Inspection
NOTE:
Removal steps in this procedure may contain installation details.
NOTE:
LH side shown, RH side similar.
Inspect the body-to-rear door dimensions...
Other information:
General Specifications
Item
Specification
Normal engine cranking speed (Average)
200-300 Revolutions Per Minute (RPM)
Starting circuit maximum voltage drop (Engine at normal operating temperature) (Average)
0...
Component Location - Blind Spot Monitoring System
Item
Description
1
PDM (if equipped)
2
RH exterior mirror
3
SODR
4
SODL
5
DDM (if equipped)
6
LH exterior mirror
..